OEM

  • Body - Cast Iron (ASTM A126 Class B)
  • Cover - Cast Iron (EN-GJL-200)
  • Hand Wheel - Ductile Iron (ASTM A536 65-45-12)
  • Non-rising stem gate valve is in the fully open position before installing the Wall Post Indicator
  • Nominal Diameter - For use with 4” to 12” NRS indicating post gate valve
  • Approvals - FM, UL, ULC
  • 11 Different Types
  • Body - AISI 304/316 Stainless Steel
  • Inner Parts - AISI 304/316 Stainless Steel
  • Connection - Flanged/Threaded
  • Nominal Diameter - Between DN15 (1/2") to DN200(4")
  • Depending on the type, maximum temperature between 180 to 210 C
  • Depending on the type, operating pressure between 16 to 63 bar
  • Body - Stainless Steel
  • Inner Parts - Stainless Steel
  • Connection - Screwed
  • Nominal Diameter - Between DN15 (1/2”) to DN50 (2”)
  • Maximum temperature - 210 C
  • Maximum pressure - 40 bar
  • Body - Cast Iron
  • Cover - Cast Iron
  • Wheel - AlSI 304 Stainless Steel + Graphite
  • Piston - 1.4104 Stainless Steel
  • Connection - Flanged
  • Nominal Diameter - Between DN15 to DN200
  • Maximum temperature - 300 C
  • Maximum pressure - 16 bar
  • Body - Cast Iron
  • Gasket - PTFE
  • Connection - Threaded
  • Nominal Diameter - Between DN15 (1/2”) to DN50 (2”)
  • Maximum temperature - 180 C
  • Maximum pressure - 16 bar
  • Air Supply Pressure Range - 3-8 bar
  • Body - Stainless Casting ASTM A743(CA 40F)
  • Cover - Stainless Steel AISI 304
  • Connection - Threaded
  • Nominal Diameter - Between 1/2” to 1”
  • Maximum temperature - 400 C
  • Maximum pressure - 42 bar
  • Body Pressure Class - PN63
  • Body - Stainless Casting ASTM A743(CA 40F)
  • Connections - G x G, G x F, F x F (G:Grooved, F:Flanged)
  • Assemble type - Vertical
  • Nominal Diameter - 3”-8”
  • Working pressure - 200-300psi
  • Approvals - FM, UL
  • Material - Stainless Steel
  • Nominal Diameter - 3/4" BSP
  • Working pressure - 200-300psi
  • Approvals - FM, UL
  • Wet type automatic sprinkler systems, retarding chambers prevent the wrong alarms, in that way it prevents the panics.
  • Material - Strong against corrosion
  • Water Enter - 3/4" BSP
  • Drainage - 1" BSP
  • Working pressure - 200-300psi
  • Approvals - FM, UL
  • Before the gong in wet alarm valve systems, strainers generally are used.
  • It use for the alarm in wet alarm systems, Generally it use after the retarding chamber. It suitable for the wall also use with the alarm valve
  • Body - Brass
  • Ball and disc - Chromed
  • Connection Type - Threaded or Grooved
  • Working Pressure - 300psi
  • Diameters - 1” - 2”
  • K Orifice - k: 80, k: 115, k: 160, k: 200, k: 242, k: 320, k: 360
  • Approvals - FM, UL, ULC